TALK=T;RUN( 1, 1)
 
 ************************************************************
   Q1 created by VDI menu, Version 2025, Date 04/11/24
 CPVNAM=VDI; SPPNAM=Core
 ************************************************************
  Echo DISPLAY / USE settings
 ************************************************************
 IRUNN = 1 ;LIBREF = 0
 ************************************************************
  Group 1. Run Title
 TEXT(Film Boiling in 2D THINC                )
 ************************************************************
  Group 2. Transience
 STEADY=F
    * Set overall time and no. of steps
 RSET(U,0.,2.,4000)
    * Modify regions
 RSET(T,1,4000,1.)
 ************************************************************
  Groups 3, 4, 5  Grid Information
    * Overall number of cells, RSET(M,NX,NY,NZ,tolerance)
 RSET(M,64,289,1,1.0E-05,1.0E-04,1.0E-03)
 ************************************************************
  Group 6. Body-Fitted coordinates
 ************************************************************
  Group 7. Variables: STOREd,SOLVEd,NAMEd
    * Non-default variable names
    * Solved variables list
 SOLVE(P1,U1,V1,SURN,VFOL,TEM1)
    * Stored variables list
 STORE(SPH1,DEN1,PRPS,MEVA,KAPA,MEVP,SIGM)
    * Additional solver options
 SOLUTN(P1,Y,Y,Y,N,N,Y)
 SOLUTN(TEM1,Y,Y,Y,N,N,Y)
 
 ************************************************************
  Group 8. Terms & Devices
 TERMS (SURN,N,N,N,N,Y,N)
 TERMS (VFOL,N,N,N,N,Y,N)
 GALA = T
 RUPLIM =0.999 ;RLOLIM =1.0E-03
 ************************************************************
  Group 9. Properties
 PRESS0 =1.01325E+05
 RHO1 =200.
 ENUL =5.0E-04
 CP1 =400.
 ENUT =0.
 DVO1DT =1.18E-04
 PRNDTL(TEM1)=-40.
   *  List of user-defined materials to be read by EARTH
    MATFLG=T;IMAT=2
   *  Name
   *Ind. Dens.  Viscos.  Spec.heat  Conduct.  Expans.  Compr.
   *  
    34 5.0 1.0E-3 200.0 1.0 3.33E-3
   *  
    78 200.0 5.0E-4 400.0 40.0 1.18E-4
 ************************************************************
  Group 10.Inter-Phase Transfer Processes
 ************************************************************
  Group 11.Initialise Var/Porosity Fields
 FIINIT(P1)=0. ;FIINIT(SIGM)=0.1
 FIINIT(PRPS)=-1. ;FIINIT(SURN)=1.
 FIINIT(VFOL)=1. ;FIINIT(TEM1)=0.
   No PATCHes used for this Group
 
 
 INIADD = F
 NAMFI   ='phida'
 ************************************************************
  Echo save-block settings for Group 11
  save11begin
REAL(LAMD0, PI, A0, A1)
CHAR(FORM1)
LAMD0=0.078684409
PI=3.1415927
A0=0.0029191916        !0.0371*LAMD0
A1=0.00059800151                     !0.0076*LAMD0
                       !FORM1=A0+A1*cos(2.0*PI*XG/0.078684409)
FORM1=A0+A1*cos(79.85299*XG)
(INIT of SURN is 0.0 with if(YG.LE.(:FORM1:)))
(INIT of VFOL is 0.0 with if(YG.LE.(:FORM1:)))
(INIT of TEM1 is 5.0-5.0*YG/:FORM1: with if(YG.LE.(:FORM1:)))
TEMP0=0.0
RSG163=0.01
  save11end
 ************************************************************
  Group 12. Convection and diffusion adjustments
   No PATCHes used for this Group
 ************************************************************
  Group 13. Boundary & Special Sources
 
 PATCH(BUOYANCY, PHASEM, 0, 0, 0, 0, 0, 0, 1, 4000)
 COVAL(BUOYANCY, U1, FIXFLU, GRND2)
 COVAL(BUOYANCY, V1, FIXFLU, GRND2)
 
 PATCH(STENS, PHASEM, 0, 0, 0, 0, 0, 0, 1, 4000)
 COVAL(STENS, U1, FIXFLU, GRND3)
 COVAL(STENS, V1, FIXFLU, GRND3)
 
 BUOYA =0. ; BUOYB =-9.81 ; BUOYC =0.
 BUOYD =5.
 EGWF = T
 ************************************************************
  Group 14. Downstream Pressure For PARAB
 ************************************************************
  Group 15. Terminate Sweeps
 LSWEEP = 50
 RESFAC =1.0E-05
 ************************************************************
  Group 16. Terminate Iterations
 LITER(P1)=200 ;LITER(SURN)=1
 LITER(VFOL)=1 ;LITER(TEM1)=200
 ENDIT(P1)=1.0E-06 ;ENDIT(TEM1)=1.0E-06
 ************************************************************
  Group 17. Relaxation
 RELAX(P1 ,LINRLX,0.5 )
 RELAX(U1 ,FALSDT,0.05 )
 RELAX(V1 ,FALSDT,0.05 )
 RELAX(SURN,LINRLX,1. )
 RELAX(VFOL,LINRLX,1. )
 RELAX(TEM1,LINRLX,0.1 )
 ************************************************************
  Group 18. Limits
 VARMAX(SURN)=1. ;VARMIN(SURN)=0.
 VARMAX(TEM1)=5. ;VARMIN(TEM1)=0.
 ************************************************************
  Group 19. EARTH Calls To GROUND Station
 SURF = T
 PARSOL = F
 IPRPSA = 78 ;IPRPSB = 34
 ISG21 = 5
 ISG62 = 1
 ISURFA = 5
 BTATHC =3.5
 ISRFTA = 1
 SURFTA =0.1 ;SURFTB=0. ;SURFTC =0. ;SURFTD=0.
 IEVAP = 2
 LATH =1.0E+04 ;TSAT=0. ;EVAPCO=0.1
 NONCON = T
 RSG163 =1000.
 CSG10   ='q1'
 SPEDAT(SET,OUTPUT,NOFIELD,L,T)
 SPEDAT(SET,SURFTENS,NSMOOTH,I,3)
 SPEDAT(SET,GXMONI,PLOTALL,L,T)
 SPEDAT(SET,VOF,LTSS,L,F)
 SPEDAT(SET,MAXINC,SURN,R,1.)
 SPEDAT(SET,MAXINC,VFOL,R,1.)
 ************************************************************
  Group 20. Preliminary Printout
 ************************************************************
  Group 21. Print-out of Variables
 OUTPUT(SURN,Y,Y,Y,Y,Y,Y)
 OUTPUT(VFOL,Y,Y,Y,N,Y,Y)
 ************************************************************
  Group 22. Monitor Print-Out
 IXMON = 1 ;IYMON = 38 ;IZMON = 1
 NPRMON = 100000
 NPRMNT = 1
 TSTSWP = -1
 ************************************************************
  Group 23.Field Print-Out & Plot Control
 NPRINT = 100000
 NTPRIN = 100000 ;ISTPRF = 1 ;ISTPRL = 100000
 ISWPRF = 1 ;ISWPRL = 100000
   No PATCHes used for this Group
 ************************************************************
  Group 24. Dumps For Restarts
 IDISPA = 25 ;IDISPB = 0 ;IDISPC = 0
 CSG1    ='A'
 
 GVIEW(P,0.,0.,1.)
 GVIEW(UP,0.,1.,0.)
 GVIEW(DEPTH,3000.)
 GVIEW(VDIS,0.117168)
 GVIEW(CENTRE,-1.714228E-03,0.08579,5.808009E-03)
 
> DOM,    SIZE,        3.934200E-02, 1.770390E-01, 1.000000E-02
> DOM,    MONIT,       3.073594E-04, 1.311604E-02, 5.000000E-03
> DOM,    SCALE,       1.000000E+00, 1.000000E+00, 1.000000E+00
> DOM,    INCREMENT,   1.000000E-02, 1.000000E-02, 1.000000E-02
> GRID,   AUTO,         F F T
> GRID,   RSET_X_1,     64, 1.000000E+00
> GRID,   RSET_Y_1,     24, 1.000000E+00
  > GRID,   RSET_Y_2,    265, 1.000000E+00
  > GRID,   RSET_Z_1,      1, 1.000000E+00
> DOM,    T_AMBIENT,   0.000000E+00
> DOM,    INI_AMB,    YES
> DOM,    INI_BUOY,   YES
 
> OBJ,    NAME,        S-WALL
> OBJ,    POSITION,    0.000000E+00, 0.000000E+00, 0.000000E+00
> OBJ,    SIZE,        TO_END,       0.000000E+00, TO_END
> OBJ,    DOMCLIP,     NO
> OBJ,    GEOMETRY,    box
> OBJ,    VISIBLE,     NO
> OBJ,    TYPE,        PLATE
> OBJ,    TIME_LIMITS, ALWAYS_ACTIVE
> OBJ,    SURF_TEMP,   0. ,5.
 
> OBJ,    NAME,        N-OUT
> OBJ,    POSITION,    0.000000E+00, AT_END,       0.000000E+00
> OBJ,    SIZE,        TO_END,       0.000000E+00, TO_END
> OBJ,    DOMCLIP,     NO
> OBJ,    GEOMETRY,    box
> OBJ,    VISIBLE,     NO
> OBJ,    TYPE,        OUTLET
> OBJ,    PRESSURE,     P_AMBIENT
> OBJ,    TEMPERATURE,  T_AMBIENT
> OBJ,    COEFFICIENT, 1000.
> OBJ,    TIME_LIMITS, ALWAYS_ACTIVE
> OBJ,    EXTERNAL,    HEAVY
 
> OBJ,    NAME,        B5
> OBJ,    POSITION,    0.000000E+00, 0.000000E+00, 0.000000E+00
> OBJ,    SIZE,        TO_END,       4.317000E-03, TO_END
> OBJ,    DOMCLIP,     NO
> OBJ,    GEOMETRY,    wirexyz
> OBJ,    VISIBLE,     NO
> OBJ,    TYPE,        NULL
 ************************************************************
STOP